Part Number Hot Search : 
LM79L05 IL79L15 4STRL NTE5850 M74HC279 01P541PL AD822 C3890
Product Description
Full Text Search
 

To Download DCW1211 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  emi conduction & radiation ems immunity compliance to en55022 class a, fcc part 15 class a compliance to en61000-4-2,3,4,5,6,8, light industry level, crit eria a 23 222 3 1 16 9 14 11 bottom view 15.24(0.60) 20.3(0.80) 12.2(0.48) 2.54( ) 0.10 2.54( ) 0.10 5.08( ) 0.20 31.8(1.25) 3.81( ) 0.15 side view 17.8(0.70) 2:1 wide input range 1500vdc i/o isolation built-in remote on/off control built-in emi filter protections: short circuit / overload cooling by free air convection five-sided shield metal case 100% full load burn-in test low cost / high reliability 2 years warranty specification file name:dcw12-spec 2011-03-08 dcw12a-05 dcw12b-05 dcw12c-05 dcw12a-12 dcw12b-12 dcw12c -12 dcw12a-15 dcw12b-15 dcw12c-15 order no. dc voltage current range rated power output switching frequency voltage range efficiency (typ.) dc current input note.5 environment safety & emc withstand voltage isolation resistance isolation capacitance working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing filter protection protection voltage accuracy a: 9 ~ 18vdc b: 18 ~ 36vdc c: 36 ~ 72vdc 400khz min. 2.0% 0.5% 0.5% 50mvp-p 60mvp-p 60mvp-p 12w 240 ~ 1200ma 100~ 500ma 80 ~ 400ma 5v 12v 15v 80% 84% 84% a: 1245ma b: 625ma c: 320ma a: 70ma b: 35ma c: 25ma i/p-o/p:1.5kvdc i/p-o/p: 100m ohms / 500vdc / 25 / 70% rh 2200pf max. 600khrs min. mil-hdbk-217f (25 ) -40 ~ +71 (refer to output load derating curve) 20% ~ 90% rh non-condensing -40 ~ +105 , 10 ~ 95% rh 0.05% / (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 31.8*20.3*12.2mm (l*w*h) or 1.25"*0.80"*0.48" inch (l*w* h) 18.5g 1.all parameters are specified at normal input, rated load, 25 70% rh ambi ent. 2. 3. . ripple & noise are measured at 20mhz by using a 12" twisted pair terminated wit h a 0.1uf & 47uf capacitor. line regulation is measured from low line to high line at rated load. 4 load regulation is measured from 20% to 100% rated load. 5.please prevent the converter from operating in overload or short circ uit condition for more than 30 seconds. 80% full load no load pi network fuse recommended 81% 84% 84% 83% 83% features : ripple & noise (max.) note.2 line regulation note.3 load regulation note.4 overload short circuit 110 ~ 180% rated output load protection type : hiccup mode, recovers automatically after fault con dition is removed all output equipped with over current protection protection type : hiccup mode, recovers automatically after fault co ndition is removed mechanical specification unit:mm(inch) pin configuration derating curve ta ( ) p i n n o . o u t p u t 1 2 & 3 9 11 1 4 1 6 2 2 & 2 3 r . c . - vi n c o m - vo u t + vo u t c o m + vi n 12w dc-dc regulated dual output converter d c w 1 2 s e r i e s 100 load (%) -40 0 25 50 71 60 60 100 0.6 + 0.2/-0 remote control power on: r.c. ~ -vin > 4vdc or open ; power off: r.c. ~ -vin < 1vdc or short


▲Up To Search▲   

 
Price & Availability of DCW1211

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X